# Integrated Series Service | IT, IC, ID and IW Units

Independent service for legacy Integrated refrigeration with IT, IC, ID and IW prefixes. Bottom condenser, column pairs, EC40 on the IC-27 and frozen drains.

Source: https://firstcoastsubzero.com/models/legacy-integrated/

---

Setpoints 38°F Fresh food 5°F Ice production 0°F Freezer

Series · IT / IC / ID / IW

# Legacy Integrated service — IT, IC, ID and IW

The Integrated cabinets with IT, IC, ID and IW plates became the Designer series, and almost all of the service revenue on the integrated platform is still in these older units.

Legacy series 2003–2022 Reviewed August 14, 2026

![A narrow view into an open refrigerated cabinet, wire shelving loaded from top to bottom.](https://firstcoastsubzero.com/img/reachin-fridge-03.webp)

Integrated cabinets hide everything except the shelf you are looking at.

Series data Integrated series data
| Series name| Integrated
| Plate prefix| IT, IC, ID, IW
| Production| 2003–2022
| Condenser| Bottom-mounted
| Sealed systems| Two — one per compartment, two compressors, two evaporators
| Water filter| 4204490 or 9030868
| Service codes| EC50, EC40

Representative models
- IC-27
- IT 30 in. column
- IT 36 in. column
- ID drawer unit
- IW wine cabinet

Series notes and exceptions Integrated exceptions
| Succeeded by| Designer, prefixes DEC, DET and DEU
| Condenser location| Bottom, behind the base grille
| Codes seen| EC50, and EC40 on the IC-27
| Sealed systems| Two on full-size and over-and-under cabinets
| Water filter| Twist-in 4204490 or 9030868

Failure profile

## What this series actually presents with.

EC40 on an IC-27 with the compartment under ten degrees above setpoint

Restricted bottom condenser. Clean it before anything else is considered

EC40 with the compartment more than ten degrees above setpoint

Component or sealed-system fault, assuming no door has been left standing open

Ice sheet across the floor of a freezer column

Frozen drain tube, then meltwater refreezing at the cabinet floor

Door no longer pulling itself closed

Hinge adjustment or panel weight after fifteen years of use

Cabinet holding in winter and failing every August

Marginal condenser capacity, restriction, or a slow loss on one sealed system

Integrated is the name the fully flush platform carried before it became Designer. The plates read IT for the column and over-and-under cabinets, IC for the integrated column range including the IC-27, ID for drawer units and IW for wine. Every one of those plates is now a legacy plate, and every one of them is still in kitchens across St. Johns County and the Jacksonville Southside doing daily work.

This is where most integrated-platform service revenue sits, and it is the reason this page exists.

## Bottom condenser, and what that costs

Integrated cabinets breathe at the base. The condenser is behind the bottom grille, unlike the Classic and legacy Built-In platform, where it is at the top behind a flip-up grille. Homeowners who have owned both are often certain their integrated cabinet has no condenser at all, because there is no visible grille at eye level.

Fifteen years of floor dust and pet hair through a low grille produces a genuinely restricted condenser. Clean it every six to twelve months, every six with pets. Two rules ride along: above 48°F in the fresh-food compartment against a 38°F setpoint, a cleaning will probably not recover it; and if the compartment has not returned to setpoint within 24 hours of a cleaning, book service.

## EC40 on the IC-27

The IC-27 is one of the cabinets that reports EC40, an excessive freezer compressor run time. The published split is the useful part.

If the compartment is less than ten degrees above setpoint, treat it as a restricted condenser and clean it. If it is more than ten degrees above setpoint, and no door has been left standing open, the cabinet needs a technician. That threshold separates a maintenance job from a component or sealed-system failure, and it does so before anyone spends money.

Leave the code displayed. Codes are logged evidence with timing attached, and on a cabinet with two sealed systems the log frequently identifies which circuit failed before anything is opened.

## Frozen drains

Fifteen-year-old integrated freezer columns freeze their drains. The symptom is an ice sheet forming on the compartment floor, or water appearing at the base of the cabinet after a warm spell.

The drain is frozen, not clogged, in the overwhelming majority of cases. Nothing rigid goes down that tube. No boiling water goes into it. The drain heater and the evaporator pan sit on the other side and a puncture converts a modest repair into a sealed-system job. The correct procedure is a controlled defrost with the door held open, then a diagnosis of the drain heater circuit, because a drain that freezes once will freeze again.

## Doors, panels and time

Integrated doors carry full-overlay panels that a cabinetmaker fitted, and after fifteen years those panels have been through at least one refinishing and sometimes a hardware change. Doors that no longer close themselves are usually an adjustment issue, sometimes a hinge, and rarely anything electrical.

None of these doors has a lock. The airtight seal makes a door feel locked for a few seconds after closing while the trapped air contracts, and it releases on its own. Forcing it tears gaskets.

## Age, boards and coverage

Around sixty-eight thunderstorm days a year in this metro put transients on residential branch circuits, and control boards on cabinets of this vintage have absorbed a lot of them. We do not publish board part numbers as definitive: fit is serial-dependent and the wrong board is expensive. We read the plate on site.

Manufacturer terms on these cabinets were two years full parts and labor, five years full sealed system and twelve years limited sealed system, parts only. An Integrated cabinet installed in 2015 or later may still be inside that twelve-year limited window. In years six through twelve the covered sealed-system part is supplied parts-only, obtained from the manufacturer directly, and an independent shop may fit it with the homeowner paying labor. On this platform that is often what makes a compressor repair rational instead of a cabinet replacement that also means new panels and new cabinetry work.

Repairs on this series
- [Freezer column](https://firstcoastsubzero.com/repairs/freezer-column/)
- [Refrigerator drawers](https://firstcoastsubzero.com/repairs/refrigerator-drawers/)
- [Wine storage](https://firstcoastsubzero.com/repairs/wine-storage/)
- [Built-in refrigerator](https://firstcoastsubzero.com/repairs/built-in-refrigerator/)

Related notes
- [EC50, EC40 and EE — read them, do not clear them](https://firstcoastsubzero.com/notes/service-codes/)
- [The drain is frozen, not clogged](https://firstcoastsubzero.com/notes/frozen-drain-tube/)
- [Years six to twelve — the coverage most owners miss](https://firstcoastsubzero.com/notes/sealed-system-coverage/)

Areas we cover
- [Mandarin](https://firstcoastsubzero.com/areas/mandarin/)
- [World Golf Village](https://firstcoastsubzero.com/areas/world-golf-village/)
- [Orange Park](https://firstcoastsubzero.com/areas/orange-park/)
- [Riverside and Avondale](https://firstcoastsubzero.com/areas/riverside-avondale/)

Coverage 12 years limited sealed system, parts only. [What that means for you](https://firstcoastsubzero.com/warranty/).

Independent service company

## Integrated service

Quote the full model and serial number from the plate. Sub-Zero control boards are serial-dependent, so we never confirm a board number from a description alone. $80 flat diagnostic, credited toward the repair.

Mon–Fri 8am–6pm · Sat 9am–4pm · Sun closed. Scheduled appointments only. No after-hours or emergency service.

[Call (904) 604-7755](tel:+19046047755) [Book online](https://nexfield.pro/crm/book?u=44) [Contact](https://firstcoastsubzero.com/contact/)

40 miles by road from Fruit Cove and St. Johns County. Drive distance, not straight-line radius.

90 days labor, 365 days parts, genuine OEM components.

EPA Section 608 certified technicians — the federal requirement to open a sealed refrigeration system.